Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 305 of 305

Display Rules

Please can the display rules work on higher parent classes like PIPING_NETWORK_SYSTEM (Pipeline) and PIPE_COMPONENT or ISO_SHEET. The idea is to write a rule to highlight all components in a pipeline where a specific criteria is met.
8 months ago in OpenPlant Modeler 0 Future consideration

Activate/Deactivate feature for reference files

OBD has Activate/Deactivate feature for reference files. This allows users to edit the reference files in the same session without switching to the reference model. Our mechanical team is currently using OBD for equipment modeling and they use thi...
4 months ago in OpenPlant Modeler 2 Future consideration

Overall Dimensioning and Spool Dimensioning

We need to have both overall dimensioning and dimensioning from spool end to spool end. This should not be an enhancement, it's a critical function.See examples. The client is requiring both dimension, but no way to generate it. We can only manual...
about 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

OPOM needs to work for Mixed Metric workset

OPOM only works properly with imperial and metric work set. Auto tagging, dimensioning and borders do not work properly when using mixed metric.
about 1 year ago in OpenPlant Orthographics Manager 0 Future consideration

Dark Theme Background

Ability to switch to a dark theme background is a standard option on most tools today.
over 1 year ago in OpenPlant Project Administrator 0 Future consideration

PCF File related Workflows

Maintain and improve ability to export PCF Files. This format allows for efficient interchange of isometric data between suppliers and different CAD systems. There will be shift towards this format in the industry. Design teams can focus on managi...
over 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Ability to import PCF files

OpenPlant Modeler users would benefit from .PCF import when there is a need to import models from other Plant Design software. This import process could, at first, bring basic routing and piping accessories, letting users select which OpenPlant sp...
over 3 years ago in OpenPlant Modeler 1 Will not implement

Possibility to change flow arrow note dimensions

When we are placing flow arrow note in our models, if the piece of pipe is too small, the placement of the note is note working well. Most of the time we have to stretch the pipe to a bigger dimensions, place the arrow and the stretch back the pip...
5 months ago in OpenPlant Modeler 0 Future consideration

Avoid raceway overfill in manual routing

Would like the option of having the software check raceway fills when manually routing cables through raceway systems in the Cable Manager and alert the user if the fill will be exceeded.
9 months ago in Bentley Raceway and Cable Management 0 Future consideration

Perform raceway size calculation using all possible routed cable

It would be helpful if the software had an option to route all cables ignoring fill and then recommend a raceway size to accommodate the required number of cables.
9 months ago in Bentley Raceway and Cable Management 0 Future consideration