Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
over 3 years ago in OpenPlant Engineering Data Manager 2 Will not implement

Have PID viewer available in Consistency manager

In file based workflow with PID to 3d, the i-model is attached so the user can see the PID against what they are modeling. We need this same viewing capability while using PlantSight with consistency manager.
over 3 years ago in OpenPlant Modeler 0 Future consideration

Weight conversion from imperial units to metric units for pipe spools

Story Narrative- A specification is created in imperial units, and when one wants to use it in metric workset the numeric value of the weights is not being converted for the pipe spools. However, the numeric value of the weights is being converted...
about 1 year ago in OpenPlant Modeler 1 Future consideration

Promote Centerlines should work for equipment

Under View Attributes - OpenPlant Modeler Settings - Promote - Centerlines only activates centerlines for piping. In orthographic drawing production, equipment also is displayed with centerlines. Centerlines should be displayed in all views of the...
about 1 year ago in OpenPlant Modeler 2 Future consideration

Enhance Model Validation Tool

Would be nice to add the following additional validation checks to the tool: Components with insulation also have the insultation thickness defined Do on-line Instruments have a defined size Do inline instruments (rotameters) line size match that ...
7 months ago in OpenPlant PID 0 Future consideration

Instrument Function - Input/Output should Prompt User for Function Variable

The user defined function symbol Input/Output requires additional properties that are defined a letter variable. The letter variables are displayed in the symbol on the P&ID. See attached images. Currently, there are no properties defined for ...
about 1 year ago in OpenPlant PID 0 Future consideration

Add Thomas&Betts raceway catalogs to metric dataset

A user requested to add the Thomas&Betts catalogs available in imperial dataset to metric dataset.
about 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Sorting of content in Custom Cell Library dialog box

Please can you enable the sorting in the custom cell dialog box. The current version of OPM sorts the custom cell placement dialog box in the order that the custom components are generated in the .cel file and with many components it is time consu...
8 months ago in OpenPlant Modeler 0 Future consideration

Ability to retain last used style in annotate dialog of OpenPlant PID

Would like to retain the last used style for a property in the annotate dialog in OpenPlant PID. Currently it reverts back to a style of "PID" the next time you load the dialog (see attached image).
8 months ago in OpenPlant PID 0 Future consideration

Ability To Add Multiple Element Template to Annotate Dialog in OpenPlant PID

Would like to have flexibility to support multiple Element templates in the Annotate Dialog Box. Currently In OpenPlantPID there is only a single option For Element Template as shown in the attached screen capture.
8 months ago in OpenPlant PID 0 Future consideration