Would like ability to rename the category labels in the Standard Preferences dialog

It would be helpful if we had the ability to rename the category labels in the Standard Preferences dialog as highlighted in the attached screen capture.
over 1 year ago in OpenPlant PID 0 Future consideration

Instrument Function - Input/Output should Prompt User for Function Variable

The user defined function symbol Input/Output requires additional properties that are defined a letter variable. The letter variables are displayed in the symbol on the P&ID. See attached images. Currently, there are no properties defined for ...
about 2 years ago in OpenPlant PID 0 Future consideration

Autofitting Filter property and SpecGrid selection

We can define this variable OPM_CUSTOM_AUTO_FIT_FILTER_PROPS = SCHEDULE to force autofitting to query elbow based on following pipe property (ex: SCHEDULE). But if we add this variable OPM_AUTOFITTING_SELECTION_GRID_FOR_ELBOW = 1 During placement ...
about 2 years ago in OpenPlant Modeler 0 Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
over 4 years ago in OpenPlant Engineering Data Manager 2 Will not implement

Have PID viewer available in Consistency manager

In file based workflow with PID to 3d, the i-model is attached so the user can see the PID against what they are modeling. We need this same viewing capability while using PlantSight with consistency manager.
over 4 years ago in OpenPlant Modeler 0 Future consideration

Generated "ISOSHEETS" in piping files be carried over to next file

When we create "ISOSHEETS" for pipelines in a design file and then try to copy all contents of this file into another file / new file (i.e reference in the file > select all content > Copy > Paste into new file > Detach the reference),...
about 2 years ago in OpenPlant Modeler 0 Future consideration

Enhance Model Validation Tool

Would be nice to add the following additional validation checks to the tool: Components with insulation also have the insultation thickness defined Do on-line Instruments have a defined size Do inline instruments (rotameters) line size match that ...
over 1 year ago in OpenPlant PID 0 Future consideration

Ability To Add Multiple Element Template to Annotate Dialog in OpenPlant PID

Would like to have flexibility to support multiple Element templates in the Annotate Dialog Box. Currently In OpenPlantPID there is only a single option For Element Template as shown in the attached screen capture.
over 1 year ago in OpenPlant PID 0 Future consideration

RBAC for Attributes or Classes in EDM

Add the ability to use the roll based access control to limit which attribute on a given tag, possibly by class, that can be edited. i.e. allowing designers to update tags from PID or Modeller, but not to change certain fields that are owned by En...
9 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Custom Components to align to pipe automatically

Please can you allow custom components to align to the pipe automatically. Placing custom components on sloped lines are very time consuming as these need to be rotated manually using 3 point rotation, which does not always work on first attempt. ...
about 3 years ago in OpenPlant Modeler 0 Future consideration