Raceway Properties should support the same UDA list selection as found in the Raceway Router

Would like to have the same UDA pick list available in the Raceway Generator dialog that is available in the Raceway Router to select a UDA list name that presets a number of UDA values so that the raceways can be generated with the proper UDA val...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Raceway Generator should allow users to select a saved UDA list like the Raceway Router dialog

Would like to have the same UDA pick list available in the Raceway Generator dialog that is available in the Raceway Router to select a UDA list name that presets a number of UDA values so that the raceways can be generated with the proper UDA val...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
about 4 years ago in OpenPlant PID 0 Future consideration

Flag PID_DOCUMENT as modified, if data on the drawing is changes.

If user deletes a tag in OPDM that already exists on a drawing. It would be nice if the PID drawing was flagged as requires syncronizaion or not up to date and when user opens the drawing in OPPID, it would show that drawing is not up to date and ...
about 4 years ago in OpenPlant Engineering Data Manager 2 Will not implement

Have PID viewer available in Consistency manager

In file based workflow with PID to 3d, the i-model is attached so the user can see the PID against what they are modeling. We need this same viewing capability while using PlantSight with consistency manager.
about 4 years ago in OpenPlant Modeler 0 Future consideration

Property Category to be Defined on the Property

Currently, when adding a property or editing an existing property, the category in which the property is to reside, is defined in a separate Custom Attribute. If a user manually adds this custom attribute, it is possible to type in an incorrect na...
8 months ago in OpenPlant PID 0 Future consideration

Improved Data Exchange with STP files

Our suppliers and customers utilize STP files to exchange equipment models to/from other authoring tools. However, the data structure of different elements is lost in Openplant. Further, when piping models are exported as STP files they do not con...
8 months ago in OpenPlant Modeler 0 Future consideration

Ability to place support nodes on Valves/Custom Components

Currently, there is no way to add support nodes to Valves or Custom Compoenets.
9 months ago in OpenPlant Modeler 1 Planned

Spec Grid Record for Operators Upon Valve Placement in OpenPlant Modeler

In OpenPlant Modeler, we have only one option to place valve, meaning we dont have valve with Open and Closed type for its placement. As per standard, for open and closed type of valve we have different operator length. At present in OpenPlant Mod...
9 months ago in OpenPlant Modeler 0 Future consideration

Avoid raceway overfill in manual routing

Would like the option of having the software check raceway fills when manually routing cables through raceway systems in the Cable Manager and alert the user if the fill will be exceeded.
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration