Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 357 of 357

Populating data from spec fields to Pipe property

The PID does not support the feature of populating data from pipe spec fields to Pipe property. At current stage it is only possible for valves.
10 months ago in OpenPlant PID 0 Future consideration

Pass new COG from model to Iso

COG is important for a spools created from Iso drawings. Knowing where the COG is on each spool makes lifting and field assembly easier and safer.
almost 3 years ago in OpenPlant Modeler 0 Future consideration

Change Spec for Custom Component

Please allow the user to edit/change the specification of Custom Component. Reusing the same custom 3D Model in different projects or in different specification requires the Custom component to be recreated from scratch each time. Trying to edit t...
almost 3 years ago in OpenPlant Modeler 1 Future consideration

Import attributes from Excel

We can Import new Pipeline list & its Properties from Excel using tag instances. But we cannot overwrite the existing values. We can export these values ( Attributes of Valves etc... ) through explorer, details items, and can be edited one by ...
over 1 year ago in OpenPlant Modeler 1 Future consideration

Improved annotation layout

Currently, users spend a lot of man hours cleaning up isometrics so that Dimension callouts and Label text do not overlap and are placed with a clean look on the isometric drawing. It would beneficial if OPIM was able to automatically perform some...
11 months ago in OpenPlant Isometrics Manager 2 Future consideration

Ability To Purge Orphaned Tags

When syncing from PID to PlantSIght a duplicate tag error is showing, but upon checking Tag Management, the tag cannot be found. Upon further check, in the Clean Tag Register, the Code State is USED, which is wrong it should not be in there anymor...
11 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Pipe components properties into Itemtypes using Expressions

This is a feature we currently use in Prostructures to get Steel information into Item types via expressions such as this.GetElement.Length(). We would like to be able to do this with Piping components in OPM which would make our exports consisten...
11 months ago in OpenPlant Modeler 0 Future consideration

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
11 months ago in OpenPlant Modeler 0 Future consideration

Display Manager Apply without closing tool

It would be useful it we could apply Display Manager settings without closing out the tool. Currently the only way to apply the display is to select OK and close the tool box. This slows down the user if they want to toggle back and forth with dis...
over 1 year ago in Bentley Raceway and Cable Management 0 Future consideration

Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc.

Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc. Similar to end condition mappings End Condition Extend Type for valves.
11 months ago in OpenPlant PID 0 Future consideration