Out of the Box Mixed Metric Workspace in OPM should show fractions in the Pipeline Manager not decimal inches

PDS piping model shows fraction for Nominal Diameter and thus reflect in Pipeline Name (ie 1 1/2"-1PA-35121-L1-N0 ). If Nominal Diameter is modified, the Pipeline Name that has a Nominal Diameter reverts to decimal nominal diameter display ( 1.5-1...
over 2 years ago in OpenPlant Modeler 0 Future consideration

BRCM CE "Auto Routing" Enhancement Observations and Recommendations for next Update 24.03

## Based on our evaluation of Update 9, we have identified the following enhancement opportunities for implementation in BRCM Update 24.03 >>> #1. Upgrade Cable/Equipment List Format: Transition the “Cable/Equipment List” file format from...
over 1 year ago in Bentley Raceway and Cable Management 1 Will not implement

Create an Advanced Query Function that can pull Class UOM

Create an ECSQL built-in function like ‘ec_clanname() and ‘ec_classid()’. It could have this form: ec_getPropertyUnit( ecclass, ecproperty ) Its functionality is to pull the component's unit of measurement (UOM).
over 2 years ago in OpenPlant Engineering Data Manager 1 Future consideration

Custom Properties in MicroStation for Elements using ECSchema via Bentley Class Editor

It would be great to have some examples for the custom properties addition to elements using the modification of ECSchema through Bentley Class Editor tool. The ECSchema is already shipped with the product. If there would be some manual related to...
over 2 years ago in OpenPlant Project Administrator 1 Will not implement

Height of Stanchion for Simple Elbow Support should be from a specific point

When a Simple Elbow Support is placed, the height of the stanchion starts at a location of the support that seems to be a random location on the elbow (see STANCHION.png). The height should be from the center of the pipe end of the elbow (see STAN...
over 2 years ago in OpenPlant Modeler 0 Future consideration

Support for variable IE_PLANTNORTH

E365 User (Tetratech) looking forward to utilize both option coordinates and rotation using variable IE_PLANTNORTH present in style.cfg file. in case there is no option to support here - then we can introduce new variable to allow user to rotate i...
about 5 years ago in OpenPlant Isometrics Manager 0 Planned

Nozzle Manager - Enable property DEVICE_TYPE_CODE to define Unique NOZZLE tag along with NUMBER.

Currently a Nozzle in Nozzle Manager is defined by the NUMBER field. When using PlantSight/OPPID/OPM, the Number needs to be defined as a Number - Not N1 or M1 (Nozzle or Manhole). Tagging of a nozzle is generally defined as EQP_NO-DEVICE_TYPE_COD...
over 2 years ago in OpenPlant Modeler 0 Future consideration

Need filter option in Spec Gen sections

Filter/search box option in individual section would be helpful in case of big specs when you have lot of classes in fittings section and you want to filter the section based on classes, end condition, catalog. Right now user has to scroll up and ...
about 5 years ago in OpenPlant Project Administrator 0 Future consideration

Generate ISO from OPM HVAC elements.

User want to Generate ISO drawings from OPM HVAC elements. They want to create ISO drawings from rectangular, oval, round HVAC duct lines.
over 5 years ago in OpenPlant Isometrics Manager 0 Future consideration

Leader line for pipeline annotations

possibility to draw leader lines for pipeline annotations if there is no space on the line.
over 5 years ago in OpenPlant PID 0 Future consideration