Ability To Purge Orphaned Tags

When syncing from PID to PlantSIght a duplicate tag error is showing, but upon checking Tag Management, the tag cannot be found. Upon further check, in the Clean Tag Register, the Code State is USED, which is wrong it should not be in there anymor...
3 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Place support on valve elements

There is no way to place support on valve element but users request this
almost 3 years ago in OpenPlant Modeler 1 Planned

AutoPLANT Objectenablers for latest AutoCAD Version

We have customer how use the current AutoCAD version (2024). This customer like to see our AutoPLANT Object (Piping, ProSteel) on there AutoCAD. In the past we always send the AutoPlant and Prosteel OE. But on Bentley side only AutoCAD 2022 get su...
12 months ago in OpenPlant Support Engineering 2 Will not implement

Coordinates Labelling Tool

The client wants coordinates add components which aren't generated by OPIM.This tool will create the box coordinates at the component the user chooses.Now it's not possible, we need to manually calculate the coordinates and place it manually.
over 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
4 months ago in OpenPlant Modeler 0 Future consideration

Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc.

Possibility to add graphical representation of counter flange for fittings like strainer, bellows, flow meter, etc. Similar to end condition mappings End Condition Extend Type for valves.
4 months ago in OpenPlant PID 0 Future consideration

Connections between different component sizes

We use OPM_MATCH_PROPERTY_MAP_NOMINAL_DIAMETER variable in our projects for Poly to Steel pipe size mapping. This variable works only when you comment out OPM_ATTRIBUTESTOCHECK variable which is not ideal solution because it allows connection betw...
6 months ago in OpenPlant Modeler 0 Future consideration

Import IsoSheets

CS0113835 There are many times when a model gets corrupted, and the only solution is to reference a model into a fresh DGN and copy all the components. However, this does not import the created IsoSheets, and users need to recreate all the IsoShee...
4 months ago in OpenPlant Modeler 0 Future consideration

BRCM for data transfer from properties fields to the data base

We need help in order to sync the BRCM properties filed to BRCM Data Base which currently not possible. Taking example of ID here If we manually edit the ID filed within properties window of raceway it allows us to edit it however the changes made...
11 months ago in Bentley Raceway and Cable Management 1 Already exists

Ability to view models from more than 1 folder location in collaboration Manager

When using projectwise and managed workspace we have models in 2 folder locations. Currently BRCM one can only see models from the location you opened the model. We need to be able to see multple folder locations as we do a lot of worksharing.
about 1 year ago in Bentley Raceway and Cable Management 1 Future consideration