When we run a Validate from Spec command, by default OPM uses SPEC ID to validate all the other properties of Piping Component. I have some older models that have duplicate SPEC IDs. If we had the ability to tell OPM to use a different property fo...
Adding Cable Laying Method drop down to Check Routing Connectivity Tool
While using the Check Routing Connectivity Tool, it would be highly beneficial to include an option to select the Cable Laying Method alongside voltage levels as routing filter. Currently, the tool shows connectivity based solely on voltage levels...
Currently in BRCM are two settings related to covers. One is located in properties of the raceway, in UDAs as "Cover Type". It's needed to use it to include covers in BOQ. Second setting is hidden in the fitting catalogue definition per raceway ty...
Raceway ID and Assignment Tool - "Export" and "Import" function
Enhance the Raceway ID and Assignment tool's functionality by incorporating the "Export" and "Import" functions, allowing for the seamless assignment of new IDs to existing segments. This streamlined ID assignment process is highly beneficial in e...
Improved Raceway Selection Across Entire Cable Route
Problem Statement In the current BRCM workflow, cables that belong to a circuit are typically routed through a common raceway path using the Includes option in Cable Manager. While this approach works in many cases, there are scenarios where it do...
AI/MCP to Generate Catalog and Spec in OpenPlant SpecGen
Hi,Does Bentley has any plan or roadmap to introduce MCP to OpenPlant? OpenPlant SpecGen has feature of create mapping and provide excel as an input for catalog creation.It would be nice to further automate this tool via AI or MS-copilot to create...
Add Connector to each Object of Multi-Object Equipment for Cable Routing.
BRCM gives the user the ability to add multiple Object to an equipment before placement but only allow one connection point. This mean that routing of cable cannot be connected to the exact object of the multi-object equipment. An MCC for example ...
Currently, you have to have a ProStructures license to use the full functionality of ProSteel in OPM204. Please can you allow the use of a ProSteel License when in OPM 2024 for steel tools and a ProConcrete License for Concrete tools in OPM2024. W...
Add Manhole, Handholes, Pullboxes IDs to Cable Routing instead of Airgap
It would be extremely important to add Add Manhole, Handholes, Pullboxes IDs to Cable Routing instead of Airgap. Currently Airgap is added into the routing and this does not give design or construction team information on where the circuit should ...
Merge into Master should be supported in OpenPlant Modeler
In MicroStation, and other design tools like OpenBuildings Designer, the reference tool -Merge Into Master is supported. In OpenPlant Modeler, this is not supported and removes the EC Data associated to the components.