Cell Library with Multi Connection Point

Please can you add multiple connection points to cell as it currently exists in Micrstation since I think version 16 or 17. In OPM you can only have the 0,0,0 point as the insertion point for normal cells.
5 months ago in OpenPlant Modeler 0 Future consideration

BOLT LENGTH FROM SPEC + WAFER JOINTS

OPM has a config variable OPM_CALCULATE_BOLT_LENGTH which controls if the tool automatically calculates the required bolt length or uses the value from the Spec. We would like to use the values defined in our spec in all cases, except for Wafer ty...
almost 3 years ago in OpenPlant Modeler 0 Future consideration

Raceway covers

Currently in BRCM are two settings related to covers. One is located in properties of the raceway, in UDAs as "Cover Type". It's needed to use it to include covers in BOQ. Second setting is hidden in the fitting catalogue definition per raceway ty...
almost 2 years ago in Bentley Raceway and Cable Management 0 Future consideration

Validate from Spec using user defined properties

When we run a Validate from Spec command, by default OPM uses SPEC ID to validate all the other properties of Piping Component. I have some older models that have duplicate SPEC IDs. If we had the ability to tell OPM to use a different property fo...
over 2 years ago in OpenPlant Modeler 1 Future consideration

Set a custom ACS in OPM and have it recognized by OPIM

Currently, OPIM does not recognize the custom ACS and only displays coordinates according to the default origin. However, it would be beneficial if we could set a custom ACS in OPM and have it recognized by OPIM. Related SR ticket: 7001541451
almost 3 years ago in OpenPlant Isometrics Manager 0 Future consideration

Intelligent Line Manager Provision Lines for Manipulation of routing

After Generating the Intelligent line into the Placeholder Pipeline instance, it would be great to be able to manipulate intelligent line before populating with 3D graphics. This is helpful during preliminary design where, intelligent lines are us...
5 months ago in OpenPlant Modeler 1 Future consideration

Ability to Check Out Pipeline or Equipment in OPM from PlantSight using key-in/Macro/VBA

Using Explorer View, PlantSIght Tab to check Pipelines and Equipment out into OPM works fine for smaller models, but when you ahve 46k Tags the process can take hours to check each individual Pipeline or Equipment out for a project. The ability to...
over 1 year ago in OpenPlant Modeler 0 Future consideration

Enhance "Quick Replace" to Display All Compatible Component Types

Problem Statement Currently, the "Quick Replace" functionality in OpenPlant Modeler restricts the replacement list to components of the exact same type. If a user wants to replace a component with a different but compatible type, they cannot do so...
about 2 months ago in OpenPlant Modeler 0 Future consideration

Raceway ID and Assignment Tool - "Export" and "Import" function

Enhance the Raceway ID and Assignment tool's functionality by incorporating the "Export" and "Import" functions, allowing for the seamless assignment of new IDs to existing segments. This streamlined ID assignment process is highly beneficial in e...
over 2 years ago in Bentley Raceway and Cable Management 2 Planned

Edit Duct Bank Fittings

The duct bank edit tools set should include a function that enables users to Edit Raceway Fittings by selecting multiple conduits and select the new parameters. The case where we have found this would be extremely helpful is when we need to change...
4 months ago in Bentley Raceway and Cable Management 0 Future consideration