Ability To Purge Orphaned Tags

When syncing from PID to PlantSIght a duplicate tag error is showing, but upon checking Tag Management, the tag cannot be found. Upon further check, in the Clean Tag Register, the Code State is USED, which is wrong it should not be in there anymor...
about 1 month ago in OpenPlant Engineering Data Manager 0 Future consideration

BOLT LENGTH FROM SPEC + WAFER JOINTS

OPM has a config variable OPM_CALCULATE_BOLT_LENGTH which controls if the tool automatically calculates the required bolt length or uses the value from the Spec. We would like to use the values defined in our spec in all cases, except for Wafer ty...
about 1 year ago in OpenPlant Modeler 0 Future consideration

Oval Instrument Parametric bubbles - Other functions

At the moment the Oval bubbles (Place Instrument Parametric) are only available as discrete instruments. Please can you extend the oval bubbles to also include the other functions like: Computer Function Distributed Digital Distributed Analog
3 months ago in OpenPlant PID 0 Future consideration

Set a custom ACS in OPM and have it recognized by OPIM

Currently, OPIM does not recognize the custom ACS and only displays coordinates according to the default origin. However, it would be beneficial if we could set a custom ACS in OPM and have it recognized by OPIM. Related SR ticket: 7001541451
about 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Ability to assign null values to Long, Int, Double type properties in OPM Schemas

Currently, it is not possible to assign null values to Long, Int, Double type properties. When a user clicks on the property, it shows "0" which does not always mean the same thing as null.
about 2 months ago in OpenPlant Modeler 0 Needs review

Consolidate Bentley Class Editior Workflows in OPPA

There are several functions such as schema modification and custom attribute addition/removal/modification that is not possible via OPPA. Users have to switch between multiple tools to complete tasks. It would be beneficial to consolidate all thes...
about 1 year ago in OpenPlant Project Administrator 0 Future consideration

Need FROM/TO for PIPING_NETWORK_SYSTEM

Hi, Currently it's only possible to get FROMs/TOs for PIPING_NETWORK_SEGMENT. It's a very important part of our engineering process/workflow to have from FROMs/TOs for a whole line (PIPING_NETWORK_SYSTEM). FROM/TO for a line can one of the followi...
about 2 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Merge into Master should be supported in OpenPlant Modeler

In MicroStation, and other design tools like OpenBuildings Designer, the reference tool -Merge Into Master is supported. In OpenPlant Modeler, this is not supported and removes the EC Data associated to the components.
about 1 year ago in OpenPlant Modeler 4 Future consideration

To/From data in Plantsight queries should be fixed

Currently when we create line list query in Plantsight and include TO/FROM fields, it shows multiple values in both fields, there should be a way to show only start and end point of pipelines, intermediate runs shouldn't be reported in the TO/FROM...
about 1 year ago in OpenPlant PID 0 Future consideration

Graphics for Bolts

We would like to have a tool which converts the symbols of bolts to real graphics as an option. Either a switching option to select symbol or real graphics while placing bolts or a macro that will convert all the bolt symbols to real graphics fetc...
6 months ago in OpenPlant Modeler 0 Future consideration