Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 313 of 313

Instrument Loops associated to Pipe Run and Pipeline

Please can you add the functionality in OPPID where the Instrument Loop is associated with Pipe Run and Pipeline? At the moment if you change the Pipeline Unit the Unit is not transferred to the Instrument Loop. This can be done by manual means bu...
3 months ago in OpenPlant PID 0 Future consideration

Ability to update properties on multiple components

CS0146120 While evaluating the data on OPM Piping Components, there are times when multiple components need to be assigned Properties. For example, we may need to update a Project Code or Shipping Status for a collection of objects that are select...
3 months ago in OpenPlant Modeler 0 Future consideration

Set a custom ACS in OPM and have it recognized by OPIM

Currently, OPIM does not recognize the custom ACS and only displays coordinates according to the default origin. However, it would be beneficial if we could set a custom ACS in OPM and have it recognized by OPIM. Related SR ticket: 7001541451
about 1 year ago in OpenPlant Isometrics Manager 0 Future consideration

Add Search for Orphaned Tags and Delete Them

Currently there is no way to see the orphaned tags, except when syncing drawings we get "found duplicates " dialog and cannot locate those tags in the PlantSight. Bentley CS has cloned the imodel few times but that didn't get rid of all orphaned t...
about 2 months ago in OpenPlant Engineering Data Manager 0 Future consideration

Consolidate Bentley Class Editior Workflows in OPPA

There are several functions such as schema modification and custom attribute addition/removal/modification that is not possible via OPPA. Users have to switch between multiple tools to complete tasks. It would be beneficial to consolidate all thes...
about 1 year ago in OpenPlant Project Administrator 0 Future consideration

Oval Instrument Parametric bubbles - Other functions

At the moment the Oval bubbles (Place Instrument Parametric) are only available as discrete instruments. Please can you extend the oval bubbles to also include the other functions like: Computer Function Distributed Digital Distributed Analog
4 months ago in OpenPlant PID 0 Future consideration

Merge into Master should be supported in OpenPlant Modeler

In MicroStation, and other design tools like OpenBuildings Designer, the reference tool -Merge Into Master is supported. In OpenPlant Modeler, this is not supported and removes the EC Data associated to the components.
over 1 year ago in OpenPlant Modeler 4 Future consideration

Calculate COG for assembly models

We are working with assemblies that are containing OPM models and ProStructure models. We would need to calculate COG of these models to facilitate liftings.
3 months ago in OpenPlant Modeler 0 Future consideration

To/From data in Plantsight queries should be fixed

Currently when we create line list query in Plantsight and include TO/FROM fields, it shows multiple values in both fields, there should be a way to show only start and end point of pipelines, intermediate runs shouldn't be reported in the TO/FROM...
about 1 year ago in OpenPlant PID 0 Future consideration

Measurement Legend will help new user to model supports fast and avoid confusion.

Currently, it can be seen, the image of support while placing in OPSE upon hovering on it. Requirement here is to get the option in placement dialogue of supports in OPSE in which one can see the image of support to place with the legend of dimens...
2 months ago in OpenPlant Support Engineering 0 Future consideration