Update UI for Change Spec Tool

The current Change Spec tool UI doesn't allow users to easily compare the old components with the new components. Why doesn't the UI show both the old data on the left, and the new data on the right in a comparable table. See attached screenshot. ...
7 months ago in OpenPlant Modeler 0 Future consideration

Have PID viewer available in Consistency manager

In file based workflow with PID to 3d, the i-model is attached so the user can see the PID against what they are modeling. We need this same viewing capability while using PlantSight with consistency manager.
over 3 years ago in OpenPlant Modeler 0 Future consideration

Weight conversion from imperial units to metric units for pipe spools

Story Narrative- A specification is created in imperial units, and when one wants to use it in metric workset the numeric value of the weights is not being converted for the pipe spools. However, the numeric value of the weights is being converted...
about 1 year ago in OpenPlant Modeler 1 Future consideration

Promote Centerlines should work for equipment

Under View Attributes - OpenPlant Modeler Settings - Promote - Centerlines only activates centerlines for piping. In orthographic drawing production, equipment also is displayed with centerlines. Centerlines should be displayed in all views of the...
about 1 year ago in OpenPlant Modeler 2 Future consideration

Sorting of content in Custom Cell Library dialog box

Please can you enable the sorting in the custom cell dialog box. The current version of OPM sorts the custom cell placement dialog box in the order that the custom components are generated in the .cel file and with many components it is time consu...
7 months ago in OpenPlant Modeler 0 Future consideration

Jacket Line Routing & Jacketed iso drawing

Currently, we are not able to route jacket pipe on the primary process pipe, and that's why iso drawings also do not get generated with jacketed line. Due to the feature is not available in Bentley, all these works like jacket MTC, and Iso drawing...
almost 2 years ago in OpenPlant Modeler 0 Future consideration

Ability to access Synchro Control from PlantSight iTwin

We want to utilize Synchro Control in the later phase our PlantSight integrated OPM project. At current stage, we can't do this as it doesn't support.
about 1 year ago in OpenPlant Modeler 0 Future consideration

Add schedule report to OPM

I would like to suggest an addition to Open Plant Modeler functionality, similar to Open Building Design. That is an option to create a schedule report, containing component attributes with the option to alter, apply and save them. Changes also ap...
over 2 years ago in OpenPlant Modeler 0 Future consideration

Actuator orientation for Relief Valve (Angle Valve)

The idea would be to be able to change the direction of the actuator when we place it on relief Valve (Angle Valve). For the moment actuator is placed aligned to the axis of the valve exit, but in real life it will be aligned to the axis of the va...
8 months ago in OpenPlant Modeler 0 Future consideration

Custom Components to align to pipe automatically

Please can you allow custom components to align to the pipe automatically. Placing custom components on sloped lines are very time consuming as these need to be rotated manually using 3 point rotation, which does not always work on first attempt. ...
about 2 years ago in OpenPlant Modeler 0 Future consideration